Call : 08045804077
Safety integrity level |
SIL3 (IEC 61508) SILCL3 (IEC 62061) |
Category | Category 4 (ISO 13849-1) |
Performance level | PL e (ISO 13849-1) |
PFHDÂ (mean probability of a dangerous failure per hour) | 1.0 x 10-9 |
TMÂ (mission time) | 20 years (ISO 13849-1) |
Safe state in the event of a fault | The N/O is open; in other words, the safety-related enabling current paths are interrupted. |
Stop category | 0 (IEC 60204-1) |
Connection type | Front connector with spring terminals |
Inputs |
2 safety inputs 1 input for reset pushbutton or external device monitoring (EDM) |
Outputs |
2 enabling current paths (safe) 2 application diagnostic outputs (not safe) 3 test pulse outputs (not safe) |
Display elements | LEDs |
Configuration method | Hard wired |
![]() |
SHIV ENTERPRISES